Moisture Vapor Barrier

Stop moisture.
Before it stops
your floor.

Moisture vapor rising through concrete is the single most common cause of epoxy floor failure. We test, document, and install the right barrier system — so the coating stays down.

Molecular Layer Visualization

See what's
happening inside.

Water vapor molecules (H₂O) migrate upward through the capillary network in concrete. When they reach the underside of a floor coating, the water vapor pressure pushes the coating away from the substrate — causing bubbles, blisters, and delamination.

A moisture vapor barrier creates a chemical seal that blocks the migration pathway. The visualization shows vapor movement with and without the barrier installed.

Toggle between Without Barrier and With Barrier installed

MVER: 8.2 lbs/1000ft²/24hr
Testing & Installation

We test before
we coat. Always.

🧪
MVER Testing

Moisture vapor emission rate testing per ASTM F1869 (calcium chloride) and ASTM F2170 (RH probe). Written results documented before any coating decision is made.

🛡️
Barrier Selection

Different moisture levels require different barrier systems. We select the product rated for your actual MVER reading — not the cheapest option or whatever is on the truck.

🏠
Residential Slabs

Basement and garage slabs on or below grade almost always warrant moisture testing before any floor coating. We include MVER testing on all residential applications.

🏭
Commercial & Industrial

Large commercial slabs — especially those poured on grade without a sub-slab vapor retarder — often have elevated moisture emissions. We test every commercial project.

🔧
Failure Remediation

Floor coating failed due to moisture? We remove the failed system, test the actual MVER, install the correct barrier, and reinstall. Warranted result every time.

📋
Written Documentation

Test results, barrier product, application rate, and cure time documented in writing. Valuable for warranty compliance and future work on the same slab.

What's Included

Test. Barrier.
Document. Done.

Most floor coating failures are moisture-related and entirely preventable. We test every job, every time — and we select the right barrier for the actual test result.

Get a Quote Failure Inspection
Moisture Vapor Barrier Service Includes
  • Calcium chloride or RH probe testing (ASTM spec)
  • Written MVER results and documentation
  • Barrier product selected for actual MVER reading
  • Surface prep and cleaning before barrier application
  • Barrier coat applied to manufacturer spec
  • Cure time observed before topcoat
  • Compatible with all epoxy and polyurea systems
  • Documentation package included
  • Workmanship warranty on barrier installation
  • Manufacturer warranty on barrier product
Albany, NY + 200 Mile Radius

Don't skip
the moisture test.

Most floor coating failures are moisture-related and entirely preventable. We test every job, every time. It's not optional.